Frazier Air Permeability Specifications and Model Comparison - 2005 Models

See the New 2009 Models

Air Permeability Tester Main Page

MS Excel Version of Chart - original

Frazier Differential Pressure Air Permeability Specifications and Comparison Chart - 2005 Models
Frazier Precision Instrument Company, Inc. - 925 Sweeney Drive, Hagerstown, MD 21740 USA
Phone (301) 790-2585   Fax (301) 790-2589
http://www.frazierinstrument.com Low Pressure High Pressure Frazier 2000 (1) Frazier 2000 (2) Low Pressure with
email: sales@frazierinstrument.com Air Permeability Air Permeability Air Permeability Air Permeability Retrofit Frazier 2000 Retrofit (1)
Model LP Model HP Model A Model AR Model LPAR
 
Manual Operation Manual Operation Computer Operation Computer Operation Computer Operation
Part Number FAP0000LP FAP0000HP FAP0000F2A FAP0000F2AR FAP0000LPAR
Pressure Drop or          
Differential Pressure Range (delta P) (8)(9) (8) (8) (8)(9) (9) (8)(9)
Differential Pressure Range - inches of H2O 0.00 to 1.00 0.00 to 0.55; 1.0 to 21.0 0.00 to 21.0 (3) 0.00 to 21.0 (3) 0.00 to 1.00 (3)
Differential Pressure Range - millimeters of H2O 0.0 to 25.4 0.0 to 14.0; 25.4 to 533.4 0.0 to 533.4 (3) 0.0 to 533.4 (3) 0.0 to 25.4 (3)
Differential Pressure Range - pascals 0.0 to 249 0.0 to 137; 249 to 5231 0.0 to 5231 (3) 0.0 to 5231 (3) 0.0 to 249 (3)
         
Permeability Range (Air Flow) (8)(9) (8) (8) (8)(9) (9) (8)(9)
Permeability Range - Cu. Ft./Sq. Ft. of Sample/Minute (5) 0.5 to 700 (4) 0.5 to 5400 (4) 0.5 to 5400 (4) 0.5 to 5400 (4) 0.5 to 700 (4)
Permeability Range - Cu. cm/Sq. cm of Sample/Second 0.5 to 356 0.5 to 2743 0.5 to 2743 0.5 to 2743 0.5 to 356
         
Measuring Accuracy - 'bias'          
Repeatablitiy of Instrument - error % of Reading +/-0.5% +/-0.5% +/-0.5% +/-0.5% +/-0.5%
Repeatablitiy among "Frazier" brand Instruments -   +/-2% (6) +/-2% (6) +/-2% (6) +/-2% (6) +/-2% (6)
error % of Reading (6)          
         
Test Methods and Standards (T1)(T2)(T3)(T4)(T5)(T6) (T1)(T2)(T3)(T4)(T5)(T6) (T1)(T2)(T3)(T4)(T5)(T6) (11) (T1)(T2)(T3)(T4)(T5)(T6)
(T7)(T8)(T9)(T10)(T11) (T7)(T8)(T9)(T10)(T11) (T7)(T8)(T9)(T10)(T11)   (T7)(T8)(T9)(T10)(T11)
(T12)(T13)(T14)(T15)(T16) (T17) (T18) (T12)(T13)(T15)(T16)(T17)(T18) (T12)(T13)(T14)(T15)(T16)(T17)(T18)   (T12)(T13)(T14)(T15)(T16)(T17)(T18)
         
Dimensions of Unit - Installed in table (12) 48"Wx24"Dx50"H (12) 48"Wx24"Dx61.5"H   (12) 48"Wx24"Dx61.5"H   (12) 11.5"Wx11.5"Dx7"H (7) 48"Wx24"Dx50"H (12)
Prices FOB or CIF Hagerstown, MD USA call or email call or email call or email call or email call or email
Notes (#):
(1) Air Permeability Tester w/ Computerized Data Collection
(2) Used to Computerize Data Collection when added to any Model of Frazier Differential Pressure Air Permeability Tester
(3) Special Order Frazier 2000 Sensors can extend range up to 200 inches; 5080 mm; 49816 pascals
(4) Air Flow Range can be extended above and below specified ranges w/ special nozzles (9 standard nozzles included) - call for additional details
(5) Often referred to as the "Frazier Number" or CFM
(6) Proprietary Frazier calibration procedures give increased repeatability not available among non-Frazier testers
(7) Dimensions of Electronic Unit
(8) Standard units for instrument are inches of H2O and Cu. Ft./Sq. Ft./Minute (specify types of optional units needed for manually operated instruments)
(9) Additional standard and user units can be easily set on computer operated units
(10) Specs of Model HP with the addition of Model AR would be the same as Model A
(11) When Model AR is added to Model LP, see Model LPAR Test Methods; When Model AR is added to Model HP, see Model A Test Methods
(12) All models can be removed from table for portability or installed in laboratory casework or production lines
Test Methods (T#):
(T1) ASTM D737; (T2) ASTM F778; (T3) ASTM D1117; (T4) ASTM D461; (T5) ASTM C522; (T6) DART 70.0; (T7) Federal Test Method #191; (T8) Federal Test Method #5450
(T9) ASA No. L154.51; (T10) Tappi T251; (T11) IST 70.1-92; (T12) ISO 9237; (T13) DIN 53887; (T14) Edana 140.1-81; (T15) JIS L1096; (T16) ASTM D3574; (T17) ASTM D6539 (T18) ISO 7231
There are many U.S. and worldwide standards that are based on the standards above - please call or email us if you have an air permeability standard that you need to use - we can let you know if our tester will perform the test.
Product prices, appearance, and specifications are subject to change at any time and do not include shipping, handling, or taxes. 
Additional Information can be found at:   http://www.frazierinstrument.com Frazier, The Frazier, Frazier Number, and Frazier 2000 are Trademarks of Frazier Precision Instrument Company, Inc.